| 1.3.0 | 10/23/2026, 7:40:50 AM UTC | minor | Re-read on 23 Oct 2026 against all 12 references: the CNT Manual PDF (7th edition, reviewed and updated 11 May 2026, 'to replace prolonged needle manipulation'), STRICTA's full text (the 90-trial survey), Han 2004, Qu and Zhang 2025 in PMC (600 and 200 microsecond pulse widths, the 1990 stimulator), the FDA BWK classification and the June 2021 panel document (21 devices, 105 articles, 28 and 17, MAUDE 1979-2020 empty, no recalls), and the five trials and reviews through Europe PMC. Every figure matches, no drift. Stamped.1 block modified |
|---|
| 1.2.0 | 10/11/2026, 9:35:20 AM UTC | minor | Re-verified all sources; CNT manual now cited in its May 2026 revision under the Council's new name, electrode chemistry, Zheng, FDA and STRICTA wordings corrected2 blocks modified- Modified – Content at Block 1
Electroacupuncture connects pa…f Colleges of Acupuncture and OrientHerbal Medicine’s
Clean Needle …Manual (https://www.ccahm.org/images/ccaom/Documents/7th_Edition_Manual_English_June_2017.pdf) (seventh edition, revised 2017ccaom/CNT_Manual.asp) (seventh edition, last updated May 2026) describes it as a
replacem…duct
poorly. It also records that the negative electrode makes the tissue around it, from a textbook of electrotherapy, that a 5 mA direct current makes the tissue at
the negative electrode alkaline and at the positive one acidic, and that what the two poles do in practic
electroacupuncture has not been worked out.
De…iting after thyroid or
neck spine surgery either a TEAS wristban…f the drug group had a nausea and vomiting score of 3 or
less on the trial’s rating0 to 10 scale, its definition of remi…in and 17 pain after
surgery or the painkillers it needs. The table gives three sham-c…width and session length, and STRICTA’sthe 2010 revision of STRICTA reports
that a survey of 90 acupuncture trials, with one of trial authors, found some of the details their checklist asks for poorly reported in the trials they surveychecklist’s
items poorly reported.
A protocol entry on Acu…rotocol) explains each field. - Modified – Sources at Block 2
|
|---|
| 1.0.0 | 10/9/2026, 3:22:59 PM UTC | major | New page: wiki expansion, sources read on drafting2 blocks added- Added – Content at Block 1
Electroacupuncture connects pairs of inserted needles to a stimulator that sends a pulsed current
between them. The US Council of Colleges of Acupuncture and Oriental Medicine’s
Clean Needle Technique Manual (https://www.ccahm.org/images/ccaom/Documents/7th_Edition_Manual_English_June_2017.pdf) (seventh edition, revised 2017) describes it as a
replacement for prolonged manual manipulation of the needle. Transcutaneous electrical acupoint
stimulation, or TEAS, sends a similar current through pads stuck to the skin over the points, with
no needle at all. The settings that distinguish one electrical treatment from another are the
frequency, the intensity, the shape of the pulse and the time it runs, and the
STRICTA reporting guideline (https://doi.org/10.1371/journal.pmed.1000261) for
acupuncture trials asks every trial that uses current to report its strength and frequency.
Frequency: 2 Hz, 100 Hz and dense-disperse
The case for choosing between 2 Hz and 100 Hz comes from the Chinese physiologist Han Jisheng. In a
2004 review of his group’s work (https://doi.org/10.1016/j.neulet.2003.12.019) , Han
reports that stimulation at 2 Hz (two pulses a second) speeds the release of the opioid peptides
enkephalin, beta-endorphin and endomorphin, that 100 Hz selectively
increases the release of dynorphin, and that alternating the two releases all four at once. He
states that clinical studies in chronic pain, including low back pain and diabetic nerve pain,
bore this out. The alternating pattern is called dense-disperse. A
2025 commentary (https://doi.org/10.1016/j.imr.2025.101221) by Fan Qu and Rong Zhang
adds that Peking University’s version of it pairs each frequency with its own pulse width,
600 microseconds at 2 Hz and 200 at 100 Hz.
Intensity, waveform and needles
The Clean Needle Technique Manual gives the current used in therapeutic electroacupuncture as
about 0.5 to 6 milliamperes (mA) and says this level should be safe in a healthy person with no
implanted electrical device. It sets the intensity by the patient’s report: the current is
turned up slowly, kept just below the level the patient feels as pain, and switched off before the
needles come out. It says muscle contraction should be avoided except where contraction is the aim,
as in some treatments for palsy, and that a session often runs 20 to 30 minutes. On
needles, it calls stainless steel safe with current, advises against silver needles, which are
softer and can break down electrically in the body with a toxic reaction, and notes that plastic handles may conduct
poorly. It also records that the negative electrode makes the tissue around it alkaline and the
positive one acidic, and that what the two poles do in practice has not been worked out.
Devices and their regulation
In the United States, electro-acupuncture stimulators have product code BWK, and the Food and Drug
Administration’s classification database (https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPCD/classification.cfm?id=BWK) lists them as unclassified because
they were on the market before the 1976 medical device amendments. At a
June 2021 advisory panel meeting (https://www.fda.gov/media/149644/download) , the FDA said it had cleared 21 such devices,
each by showing it was substantially equivalent to one already sold, and proposed making them class
II devices with special controls: tests of biocompatibility, sterility, electrical and thermal
safety and electromagnetic compatibility, and labelling that states the device’s electrical
output. The FDA’s own description of the device type covers both needle and skin electrodes,
and states its principle as the stimulation of acupuncture points influencing parts of the body
that are not next to them. The database still listed the code as unclassified when this page was
checked.
TEAS: current through the skin
Qu and Zhang define TEAS as stimulation of acupuncture points by current from paired electrodes on
the skin surface, and trace it to 1990, when Han’s team built a stimulator that combined the
technology of transcutaneous electrical nerve stimulation (TENS) with acupuncture point selection
and the alternating 2 and 100 Hz pattern. A 2026
survey of trial registries by Yilong Liu and colleagues found 239 trials of TEAS around surgery
registered between 2012 and 2025, with the number rising in 2024.
A 2026 trial in JAMA Surgery (https://doi.org/10.1001/jamasurg.2025.6394) by
Zheng and colleagues gave 232 women with moderate to severe nausea and vomiting after thyroid or
neck surgery either a TEAS wristband over PC06 (/points/PC06) (Neiguan) for
2 hours with a saltwater injection, or an inactive wristband with the anti-sickness drug
metoclopramide. After 2 hours, 77.6% of the TEAS group and 55.2% of the drug group had a nausea score of 3 or
less on the trial’s rating scale, its definition of remission.
Nausea after surgery (/wiki/evidence/nausea-after-surgery) reports the reviews of PC6
stimulation.
How TEAS differs from TENS
Both send current through skin pads, and the difference is where the pads go and why. A TENS
trial puts them at or near the pain: that is the inclusion rule of a
2022 meta-analysis (https://doi.org/10.1136/bmjopen-2021-051073) by Mark Johnson and
colleagues, which included 381 randomised trials with 24,532 participants. Across the 91 trials
that compared TENS with a placebo, pain was lower during or straight after TENS, and the authors
rated that evidence moderate certainty; adverse events were poorly reported. A TEAS trial places the
pads on acupuncture points, which can be far from the complaint, as with the wrist point used for
nausea in the trial above.
How electroacupuncture appears in trials
The FDA’s 2021 literature review (https://www.fda.gov/media/149644/download) found 105 relevant human
studies published from 2010 to 2020, of which 42 concerned musculoskeletal pain and 17 pain after
surgery. The table gives three sham-controlled trials of electroacupuncture with several hundred
participants each.
Three large sham-controlled trials of electroacupuncture
Trial
Participants
Treatment and control
Main result
Liu and colleagues, Annals of Internal Medicine, 2016 (https://doi.org/10.7326/M15-3118)
1,075 people with chronic severe functional constipation, 15 hospitals in China
28 sessions over 8 weeks at traditional points, or sham electroacupuncture at non-points
Complete spontaneous bowel movements rose by 1.76 a week against 0.87 with sham (difference 0.90, 95% CI 0.74 to 1.10)
Liu and colleagues, JAMA, 2017 (https://doi.org/10.1001/jama.2017.7220)
504 women with stress urinary incontinence, 12 hospitals in China
18 sessions over 6 weeks in the lower back, or sham with no skin penetration
Urine leakage on a 1-hour pad test fell by 9.9 g against 2.6 g (difference 7.4 g, 95% CI 4.8 to 10.0)
Tu and colleagues, Arthritis & Rheumatology, 2021 (https://doi.org/10.1002/art.41584)
480 people with knee osteoarthritis
Electroacupuncture, manual acupuncture or sham, 3 times a week for 8 weeks
Response at week 8 in 60.3%, 58.6% and 47.3%; electroacupuncture differed from sham by 13.0 points (97.5% CI 0.2 to 25.9), manual acupuncture by 11.3 (−1.6 to 24.4)
The constipation trial notes that the acupuncturists could not be blinded. AcuiQ’s pages on
constipation (/symptoms/constipation) ,
stress urinary incontinence (/symptoms/incontinence-urinary-stress) and
knee osteoarthritis (/symptoms/osteoarthritis-knee) list the protocols individual studies
prescribed, each with its citation.
Safety
Of the 105 studies in the FDA’s review, 28 reported on safety and 17 reported adverse events
linked to electroacupuncture, which the FDA listed as ranging from mild fainting, bruising and
nausea to loss of consciousness and death; its search of its own adverse event database from 1979
to 2020 found no reports under the product code, and it found no recalls. The Clean Needle
Technique Manual advises against any circuit that crosses the chest from one side to the other,
crosses the spine, or runs near the brainstem or the front of the neck, and against
electroacupuncture in anyone with a pacemaker or implanted defibrillator.
Electrical stimulation and implants (/wiki/safety/electrical-stimulation-and-implants)
covers implanted devices in full.
What the sources cannot tell you
Han’s findings describe which peptides each frequency releases; they do not show that one frequency serves a
given condition better than another. The trials in the table compare electroacupuncture with a sham,
and the one that also ran manual acupuncture compared each with sham rather than with each other.
Trials also differ in intensity, pulse width and session length, and STRICTA’s authors found
some of the details their checklist asks for poorly reported in the trials they surveyed.
A protocol entry on AcuiQ names how the study delivered it, and electroacupuncture and electrical
stimulation on the skin are separate modalities there; the entry does not record frequency or
current. Reading a protocol (/wiki/method/reading-a-protocol) explains each field. - Added – Sources at Block 2
|
|---|